Version 5 (modified by 12 years ago) ( diff ) | ,
---|
: 00000000b 00 00 00 00 00 00 00 00 ID0 ID1 ID2 ID3 ; 00000000b --- bit.0=Data Length Code bit.0 bit.1=Data Length Code bit.1 bit.2=Data Length Code bit.2 bit.3=Data Length Code bit.3 bit.4=extended ID or Standard bit.5=RTR message or Normal 00 00 00 00 00 00 00 00 --- DATA bytes ID0 ID1 ID2 ID3 --- CAN ID
to send a CAN message: 3Ah,3Dh,(X), ID0,ID1,ID2,ID3, byte0,byte1,byte2,byte3,byte4,byte5,byte6,byte7 (number of bytes depends on (X) value) (X) is bitmapped value: i.e. 00111000b bit3 bit2 bit1 bit0 defines number of DATA bytes to send on CAN BUS 1000b will send 8 bytes, (when CANex module receives (X) with last 4 bits equal 1000b, it will expect 4 bytes for ID + 8 bytes for DATA bytes to send) bit4 is CAN EXTENSION bit normaly =1 for NMEA bit5 is RTR mark, normaly =0 bit6 and bit7 MUST BE 0 !!!!!!!! SAMPLE FOR TERMINAL $3A$3D$17$11$0B$F5$0D$01$01$08$00$00$00$01
Note:
See TracWiki